Powerscout CT Comparison

 

Eletepro XC

Portable Power Data Logger

ELITEpro XC™ Portable Power Data Logger

PowerScout 3037

Power Submeter

PowerScout 3037 Power Submeter

PowerScout 12 HD

Multi-Circuit Power Submeter

PowerScout 12 Multi-Circuit Power Submeter

PowerScout 48 HD

Multi-Circuit Power Submeter

PowerScout 48 Multi-Circuit Power Submeter
 

Eletepro XC

Portable Power Data Logger

ELITEpro XC™ Portable Power Data Logger

PowerScout 3037

Power Submeter

PowerScout 3037 Power Submeter

PowerScout 12 HD

Multi-Circuit Power Submeter

PowerScout 12 Multi-Circuit Power Submeter

PowerScout 48 HD

Multi-Circuit Power Submeter

PowerScout 48 Multi-Circuit Power Submeter
Typical Applications/Usage Measurement and Verification (M&V) studies, electrical load profiling, energy audits, new technology assessment studies. The ELITEpro XC is typically installed inside an electrical panel for a finite period of time (weeks to months). Tenant submetering (shopping malls, apartments, office spaces, etc), net metering, data center monitoring or other commercial/industrial applications. The PowerScout 3037 is not meant to be a stand alone energy recorder. They are designed to connect as a slave device to a data logger, Remote Terminal Unit (RTU), or building management host network. Tenant submetering (shopping malls, apartments, office spaces, etc), net metering, data center monitoring or other commercial/industrial applications. The PowerScout 12 HD is not meant to be a stand alone energy recorder. They are designed to connect as a slave device to a data logger, Remote Terminal Unit (RTU), or building management host network. Tenant submetering (shopping malls, apartments, office spaces, etc), net metering, data center monitoring or other commercial/industrial applications. The PowerScout 48 HD is not meant to be a stand alone energy recorder. They are designed to connect as a slave device to a data logger, Remote Terminal Unit (RTU), or building management host network.
Service Types Single Phase, Split Phase, Three Phase-Four Wire (WYE), Three Phase-Three Wire (Delta), DC Systems (Solar/Battery) Single Phase, Split Phase, Three Phase-Four Wire (WYE), Three Phase-Three Wire (Delta) Single Phase, Split Phase, Three Phase-Four Wire (WYE), Three Phase-Three Wire (Delta) Single Phase, Split Phase, Three Phase-Four Wire (WYE), Three Phase-Three Wire (Delta)
Voltage Channels 3 channels, CAT III, 0-600 VAC (line-to-line) or 600 VDC 80-346 Volts AC Line-to-Neutral, 600V Line-to-Line, CAT III. 90-346 Volts AC Line-to-Neutral, 600V Line-to-Line, CAT III. 90-346 Volts AC Line-to-Neutral, 600V Line-to-Line, CAT III. Two voltage reference inputs.
Current Channels 4 channels, .67 VAC max, +/- 1 VDC. Ideal for 333 mV full scale CTs 3 channels, 0.525 VAC max, 333 mV CTs, 0-4,000+ Amps
depending on CT
12 channels, 0.525 VAC max, 333 mV CTs, 0-4,000 Amps depending on CT 48 channels, 0.525 VAC max, 333 mV CTs, 0-4,000 Amps depending on CT
Maximum Current Input External transducer dependent.
200% of current transducer rating (mV CTs)
Measure up to 6000A with RoCoil CTs.
158% of current transducer rating (mV CTs) to maintain accuracy.
Measure up to 4000A with RōCoil CTs
150% of current transducer rating (mV CTs) to maintain accuracy. Measure up to 4000A with RōCoil CTs 150% of current transducer rating (mV CTs) to maintain accuracy. Measure up to 4000A with RōCoil CTs
Analog Channels 4 channels, 0-10 Volts, 0-20 or 4-20 mA current loop. Non-isolated, external power for current loop. User scaling for sensor reporting in physical units. N/A N/A N/A
Measurement Type True RMS using high-speed digital signal processing (DSP) True RMS using high-speed digital signal processing (DSP) True RMS using high-speed digital signal processing (DSP) with continuous sampling True RMS using high-speed digital signal processing (DSP) with continuous sampling
On Board Memory 16 MB non-volatile. Depending on the setup table, any measurement can be recorded at the integration period with a time stamp. N/A Energy (kWh) values are recorded every 15 minutes for 63 days (downloadable log) Each record is time stamped Energy (kWh) values are recorded every 15 minutes for 63 days (downloadable log) Each record is time stamped
Line Frequency DC/50/60 Hz 50/60 Hz 50/60 Hz (45-70 Hz measurable range). Measurement taken L1-N. 50/60 Hz (45-70 Hz measurable range). Measurement taken L1-N.
Waveform Sampling 12 kHz
200 samples/cycle at 60Hz
240 samples/cycle at 50Hz
12 kHz 1.8 kHz 1.8 kHz
Parameter Update Rate 8 Hz or every 125 mSec. 0.5 seconds 1 second 1 second
Blind Cycles 8 Hz or every 125 mSec. 0.5 seconds None None
Integration Period 1, 3, 15, 30 seconds; 1, 2, 5, 10, 15, 20, and 30 minutes; 1 and 12 hours, 1 day N/A 15 minutes 15 minutes
Energy Measurements Volts, Amps, Amp-Hrs (Ah), kW, kWh, kVAR, kVARh, kVA, kVAh, Displacement Power Factor (dPF). All parameters for each phase and for system total. Volts, Amps, kW, kVAR, kVARh, kVA, kVAh, aPF, dPF, kW demand, kVA demand, Import (Received) kWh, Export (Delivered) kWh, Import (Received) kVAh, Export (Delivered) kVAh, Import (Received) kVARh, Export (Delivered) kVARh, Frequency. All parameters for each phase and system total. Volts, Amps, kW, kVAR, kVA, aPF, dPF, kW demand, kVA demand, Import (Received) kWh, Export (Delivered) kWh, Net kWh, Import (Received) kVAh, Export (Delivered) kVAh, Net kVAh, Import (Received) kVARh, Export (Delivered) kVARh, Net kVARh, THD, Theta, Frequency. All parameters for each phase and element total. Volts, Amps, kW, kVAR, kVA, aPF, dPF, kW demand, kVA demand, Import (Received) kWh, Export (Delivered) kWh, Net kWh, Import (Received) kVAh, Export (Delivered) kVAh, Net kVAh, Import (Received) kVARh, Export (Delivered) kVARh, Net kVARh, THD, Theta, Frequency. All parameters for each phase and element total.
Accuracy Better than 1% (<0.2% typical) for V, A, kW, kVAR, kVA, PF, Analog 0.2% ANSI C12.20-2010 Class 0.2 0.2% ANSI C12.20-2010 Class 0.2 0.2% ANSI C12.20-2010 Class 0.2
Resolution 0.01 Amp, 0.001 Volt, 1 Watt, 1 VAR, 1 VA, 0.01 PF, 0.001 Analog 0.01 Amp, 0.1 Volt, 0.01 Watt, 0.01 VAR, 0.01 VA, 0.01 Power Factor
depending on scalar setting
Values in IEEE-754 single precision floating point format (32 bit). Values in IEEE-754 single precision floating point format (32 bit).
LED Indicators Tri-color (red, green, blue): 1 LED indicates communication (blue for wireless, Bluetooth® or Ethernet), 4 LEDs for correct phasing (PhaseChek™). Communications, pulse output, and PhaseChek N/A N/A
Display None Optional 2 x 16 character display which auto-cycles between
screens; real-time values updated every second
Optional 4-line display, tri-color backlight (PhaseChek™) Optional 4-line display, tri-color backlight (PhaseChek™)
Line Power From L1 Phase to L2 Phase. 80-600V (AC or DC) CAT III DC/50/60 Hz, 125 mA, 5 W, or 10 VA max. Non-user replaceable .5 Amp internal fuse protection. From L1 Phase to L2 Phase. 80-600VAC CAT III 50/60Hz, 90mA Max. Non-user
replaceable .5 Amp internal fuse protection
From L1 Phase to L2 Phase. 90-600VAC RMS CAT III 50/60Hz, 500mA AC Max. Use of 12 volt auxiliary output requires 100 VAC minimum input voltage. From L1 Phase to L2 Phase. 90-600VAC RMS CAT III 50/60Hz, 500mA AC Max. Use of 12 volt auxiliary output requires 100 VAC minimum input voltage.
Auxiliary Power In 6-10 VDC, 500 mA USB USB USB
Power Out 6 VDC, 200 mA max Unregulated 5VDC output, 140 mA max Unregulated 12VDC output, 200 mA, self-resetting fuse. Unregulated 12VDC output, 200 mA, self-resetting fuse.
Pulse Output N/A Open Collector, optically isolated, 5mA max current, 30V max open
voltage
N/A N/A
Pulse Input N/A N/A Four inputs. 3.3V sourcing voltage (current limited) to customer dry contact pulse output. Max pulse rate 10 Hz (50 mSec minimum transition time). Two inputs. 3.3V sourcing voltage (current limited) to customer dry contact pulse output. Max pulse rate 10 Hz (50 mSec minimum transition time).
Alarm Output N/A N/A Over/Under Voltage & Current (SPDT Relay - 30 VDC) Over/Under Voltage & Current (SPDT Relay - 30 VDC)
USB USB standard (Type B). 1.8 M (6 ft) A-to-B USB Cable (included) USB standard (Type B). For configuration only. USB standard (Type B). For configuration only or downloading of logged data. USB standard (Type B). For configuration only or downloading of logged data.
Ethernet Standard Ethernet. Configure for DHCP or Static IP. Optional Ethernet. Configure for DHCP or Static IP. Standard Ethernet. Configure for DHCP or Static IP. Standard Ethernet. Configure for DHCP or Static IP.
Bluetooth Optional. Internal antenna with 10-100 ft range (typical). Requires Bluetooth® wireless technology adapter on Windows PC. Adapter must support the Serial Port Profile (SPP). N/A N/A N/A
Wi-Fi Optional. Wi-Fi option available as two separate configurations:
• Internal antenna: typical range 75-300 ft.
• External 3 dbi antenna: typical range 150-300 ft.
N/A N/A N/A
Modbus N/A Modbus RTU (RS-485) or Modbus TCP Modbus RTU (RS-485) or Modbus TCP Modbus RTU (RS-485) or Modbus TCP
BACnet N/A BACnet MS/TP (RS-485) or BACnet IP BACnet MS/TP (RS-485) or BACnet IP BACnet MS/TP (RS-485) or BACnet IP
Supported Baud Rates N/A Modbus: 9600 (Default), 19200, 38400, 57600, 76800, 115200 baud
BACnet: 9600, 19200, 38400, 57600, 76800 (Default), 115200
9600 (Default), 19200, 38400, 57600, 76800, 115200 9600 (Default), 19200, 38400, 57600, 76800, 115200
Operating Temperature -7 to + 60 °C (20 to 140 °F) -7° to 60°C (-20° to 140°F) -20° to 60°C (-4° to 140°F) -20° to 60°C (-4° to 140°F)
Operating Humidity 5% to 95% non-condensing 5% to 95% non-condensing 5% to 95% non-condensing 5% to 95% non-condensing
Enclosure Type ABS plastic, 94-V0 flammability rating ABS Plastic, 94-V0 flammability rating ABS Plastic, 94-V0 flammability rating. Connections: 1” EMT conduit ABS Plastic, 94-V0 flammability rating. Connections: 1” EMT conduit
Circuit Board Only Option N/A N/A Circuit board on mounting plate available Circuit board on mounting plate available
Weight 340 g (12 ounces) 340 g (12 ounces) 1043 g - 1452 g (2.3 - 3.2 lbs) depending on configuration 1814 g - 2223 g (4.0 - 4.9 lbs) depending on configuration
Dimensions (L) 21.6 cm x (W) 6.3 cm x (H) 4.7 cm (8.5” x 2.5” x 1.9”) (L) 24.2 cm x (W) 8.5 cm x (H) 4.0 cm (9.5” x 3.3” x 1.6”) Enclosure: (L) 24.8cm x (W) 25.1cm x (H) 8.0 cm (9.8” x 9.8” x 3.1”)
Mounting Plate: (L) 17.8cm x (W) 26.3cm x (H) 8.0 cm (7.0” x 10.4” x 3.1”)
Enclosure: (L) 33.7cm x (W) 25.1cm x (H) 8.0 cm (13.3” x 9.8” x 3.1”)
Mounting Plate: (L) 26.2cm x (W) 24.1cm x (H) 8.0 cm (10.3” x 9.5” x 3.1”)
Mounting Options Mounting tabs or magnets Mounting tabs or TS35/7 DIN Rail Panel Mount/Enclosure Panel Mount/Enclosure
UL UL Listed- Conforms to UL Std 61010-1
Certified to CSA Std C22.2 No.
61010-1
UL Listed- Conforms to UL Std 61010-1, 3rd Edition & IEC 61010-2-030 1st
edition
Circuit Board on Plate: UL Recognized-Conforms to UL Std 61010-1 3rd Edition
Certified to CSA Std C22.2 No. 61010-1 3rd Edition
Enclosure Version: UL Listed-Conforms to UL Std 61010-1 3rd Edition
Certified to CSA Std C22.2 No. 61010-1 3rd Edition
Circuit Board on Plate: UL Recognized- Conforms to UL Std 61010-1 3rd Edition
Certified to CSA Std C22.2 No. 61010-1 3rd Edition
Enclosure Version: UL Listed- Conforms to UL Std 61010-1 3rd Edition
Certified to CSA Std C22.2 No. 61010-1 3rd Edition
CE EN 61000-6-4: Class A EN 61000-6-4: Class A EN 61000-6-4: Class A EN 61000-6-4: Class A
ANSI C12.20 Class 0.2 N/A NIST Traceable Calibration NIST Traceable Calibration NIST Traceable Calibration