PowerScout™ 3 Plus Networked Power Meters - Submeters
(Also see PowerScout Series Overview)


Power Meters by DENT



 
data logger  - dataloggers - datalogger - loggers

PowerScout™ High Performance Instruments
Deliver Accurate On-Demand Energy
Consumption Data


PRESS RELEASE:
New PowerScout™ 3 Plus Launched...


PRESS RELEASE: DENT is a Winner in ACHR News Dealer Design Awards...

 

DENT's PowerScout™ 3 Plus is a single-point 3-phase submeter that is compatible with either BACnet or Modbus communications protocols. It was designed to provide timely and accurate consumption data necessary to gain the upper hand on electrical costs in today's escalating energy market. These meters can capture kWh/kW energy and demand data as well as virtually all relevant energy parameters for diagnostics and monitoring. PowerScout 3 Plus meters meet the stringent ANSI C12.20-2010 Class 0.2 accuracy standard.

The PowerScout's flexibility, size, and ease-of-use make them ideal tools for gathering detailed consumption information in commercial, industrial, government and retail environments.

Installing the PowerScout 3 Plus is simple thanks to color-coded voltage leads and clearly labeled CTs. DENT's patented PhaseChek™ circuitry includes a three LED indicator display that confirms proper CT-to-phase installation. The PowerScout 3 Plus automatically adjusts for CT orientation, greatly reducing set-up time and all but eliminating installation errors.

The PowerScout 3 Plus uses direct connections to each phase of the voltage and various pre-wired CT options such as split-core current transformers or flexible Rogowski coils (for large loads or large cables and busbars) to monitor current on each phase.

The communications interface to the PowerScout 3 Plus is an RS-422/485 serial connection that uses the BACnet Master Slave Token Passing (MS/TP) protocol or Modbus protocol for sending commands and retrieving data. A separate BACnet client (Data Logger, or Building Management and Control System) is usually connected to the PowerScout 3 Plus for BACnet. A separate remote terminal unit (RTU), Data Logger, or Building Management and Control System is usually connected to the PowerScout 3 Plus for Modbus mode. This separate unit provides data recording and trend logging plus a human interface or display.

Up to 127 PowerScout 3 Plus meters may be connected to a single BACnet client for monitoring and recording power usage at multiple locations within a single site. Up to 254 meters may be connected to Modbus.

Get a Quote
Call 1-800-388-0770 or
email us here.
Contact an Expert

Key Features:

  • Over 50 measured parameters for energy measurement, monitoring and diagnostics
  • Single or 3-phase energy and power meter for submetering applications
  • Mix-and-match a full range of Split-Core or RoCoil™ Rogowski-style current transformers
  • Patented PhaseChek™ LED indicators ensure correct CT orientation during installation.
  • Line-Powered; 60-600V Phase-Phase Power Supply (Use on 120/240V, 208/120V, 480/277V, or 580/335V, 380/220 volt services; 50 or 60 Hz
  • Switchable between industry-standard Modbus Communications and BACnet (MS/TP) Protocol.
  • Data updates occur every 0.5 seconds
  • ETL and CE Mark
  • Accuracy: Meets ANSI C12.20-2010 Class 0.2 Standard
  • Typical Applications
    • Submetering for accurate accountability to tenants, process lines, departments, or entire buildings.
    • Baseline Measurement and Verification of energy savings retrofits or upgrades. Benchmark pre- and post-retrofit consumption and savings.
    • Data Center Load Monitoring on servers and auxiliary equipment to optimize data center operations.
    • Demand Response or Load Shedding programs to take advantage of lowered utility rates.

Related Documents:

 

 
Give us your challenge,  
frustration or a specific  
request:  
Give us Your Challenge....
First Name  
Last Name  
Email  
Company  
Telephone  
Address  
City/State/Zip  
 
Country  
  Much appreciated if you would please tell us which engine, site or source referred you to us? If via search engine, what search words did you use?
Engine, site, source  
Search words used  

















© 2011   DENT Instruments  |  925 SW Emkay Drive  |  Bend, Oregon 97702  |  541.388.4774  -  800.388.0770  |  fx 541.385.9333
Home  |  About DENT Instruments  |  Product Overview  |  Applications & Case Studies  |  Recent Press  |  Freq. Asked Questions  |  Contact Support
Get a Quote  |  Find a DENT Distributor  |  Contact DENT Instruments  |  E-Newsletter Sign-up  |  Career Opportunities