What's the difference between displacement and apparent
power factor? Displacement power factor is the ratio of the
fundamental (60 Hz) real power to apparent power. Apparent power factor
is a ratio of total real power (including harmonic component) to apparent
power.
-
How
can there be a Power Factor of .87 on a 3-Phase Delta lighting load? The line currents in a delta are shifted 30° compared to the line-line
voltage. One line current will be shifted +30° and the other line current
shifted -30° when compared to the line-line voltage. Since power factor is
COS(theta), then COS 30° = .866. This will be true for the hardware
channels. If the power sum channel (5 or 6) is used, the power factor for the
whole load should be as expected.
-
Why
am I seeing negative Watts on one phase of a 3-Phase Delta system? The line currents in a delta are shifted 30° compared to the line-line
voltage. When connected to a load that has a PF of <.5 (>60°) (e.g. a
motor not fully loaded) one line current becomes shifted >90° (30°
+>60°) when compared to the line-line voltage. The other phase is
shifted >30° (-30° + >60°). The COS of an angle >90°
is negative, therefore WATTs = COS(theta)VA is negative for that phase.
However, as with the power factor the sum of the watts in a delta should be
positive. If not, check the CT orientation, one or both may be reversed. Also
check to make sure the CTs are referenced to the correct line voltages.
-
Can
I use the software to assist in verifying a current transformer
connection? Yes. If no current transformer is connected to a
channel that is turned on, then a non-zero reading will be displayed. If
the CT is connected but shows a '0' for a value, then the CT is probably
connected but the monitored load is turned off. On the other hand if a
constant value for current is displayed, a CT wire may have come off of the
logger.
- Is the battery on my DENT logger rechargeable? No. All DENT loggers have single-use Lithium cell batteries that cannot be recharged and should be disposed of properly. Please contact DENT Instruments for replacement batteries.
|
|
|
ELITEpro™
and DATApro™ Instruments |
|
-
What
is "Integration (or Recording) Interval"? These are the periods
that the logger will post data for. You can use 3, 15, or 30 sec., 1, 2,
5, 10, 15, or 30 min., or 1, 12, or 24 hour interval periods with the
ELITEpro. All recorded values will have a time stamp using one of the
above periods.
- How exactly does an ELITEpro gather data to record a sample? There are two answers to this question: (1) for situations where your ELITEpro is running on battery power only and (2) in situations where your ELITEpro is using external (wall) or Line-Power.
- (1) A logger using battery power only will sleep until the desired interval. Upon reaching the interval, the logger will wake up, take one sample and go back to sleep. So, for example, if you are set for a 5 minute integration period, then logger will sleep until the specified interval, then wake, record a sample, then go back to sleep again for another 5 minutes--it will continue to repeat this pattern.
- (2) If the logger is using external power, it will take a sample every 3 seconds regardless of the specified recording interval. So for example, if you are set for a 5 minute integration period, the logger will take a sample every 3 seconds and then use all 100 samples taken to find the Average, Minimum, and Maximum readings.
- What exactly happens when an ELITEpro records a sample? When a sampling interval occurs, the ELITEpro measures 128 points along a single 360° cycle for each phase being measured. It then calculates RMS values for each point and records the product for each requested sample as determined by the setup table.
-
What
is "Waveform Sampling"? This is the process of digitizing an
analog waveform. The logger has a sampling frequency of 7.68kHz (128
points per waveform). The ELITEpro uses two 12 bit A/D to sample both
current and voltage waveforms simultaneously. The data points from the
waveform sampling are used for all calculations.
-
Why
will the ELITEpro not allow me to set my integration interval at 30
seconds? Most likely it is because you are powering the
instrument from the internal batteries. When running from the internal
batteries the rate at which it will sample is once per minute. This
preserves the batteries. When sampling on external power (9V transformer)
the instrument senses the power and switches into a fast sampling mode (once
every 3 seconds).
- How fast can I sample with the DENT ELITEpro logger? Every three seconds is the fastest sampling rate at which the ELITEpro can record data. In order to record at less than one minute intervals, the ELITEpro must be either plugged into a wall outlet, or, if the unit has the 'Line-Power' option, drawing out power through the voltage leads. One minute is the fastest sampling rate for an ELITEpro using battery power only.
-
I'd
like to use my own CT's. What voltage output will be compatible with the DENT
Instruments? The CT inputs of the
ELITEpro can handle a maximum of 450mV or AC or DC current. All of the
CT's provided by DENT Instruments are shunted to output
0-333mVAC at rated current.
-
Ive got a remote site with no electrical and no phone
line. How do I get the data?The logger can use a external cell
modem to provide data transfer from a remote location. Cell phone modems
can be connected to the loggers serial port and provide a baud rate of 2400
baud. There is an option in PC Setup to set the software for extended
timeouts for cellular communications. This feature will add timing delays
and prevent dropouts. You can use AUTOPOLL, AUTOHOST or the manual dial
features to retrieve logger data.
-
How
long does the battery last and is it replaceable? Battery life
for the PRO series instruments is generally 3 years. The standard
instrument uses on lithium C cell and the modem instrument uses two lithium C
cells. The batteries are in holders and are easily
replaceable. Contact the factory for availability and instructions. Note: Use the wall transformer whenever possible as this
provides external power to the instrument and extends battery
life.
-
What
is the modem capability? The internal modem of the PRO series
instruments is 14.4k baud.
-
How
will I know if I have sufficient memory to complete my study? The
best way to calculate the memory is in the first page of a setup table.
Create the set up table in ELOG and view the calculated memory from the first
page of the set up table. You can alter the table easily and see how it
affects total memory.
-
Can
I use the ELITEpro to monitor 400Hz (military) loads? Yes! Simply set the logger to 50Hz on the
first page of the Set Up Table. At 400Hz, the logger will sample at 16
times per cycle. This method works very well as long as there is little
harmonic current beyond the 7th harmonic (2800Hx).
-
When
I compare the ELITEpro measurements on three phase loads with another meter, I
notice that the watts and VAR's agree but VA and Power Factor do not.
Why? The usual reason is that the two meters are not
calculating VA and Power Factor in the same way. Some meters include
harmonics in the calculation and some do not. The ELITEpro can do both
depending on whether the 2 watt-element method is being used (does not include
harmonics) or the 3 watt-element method (does include harmonics).
-
What is the difference between the ELITEpro and the
DATApro? The ELITEpro is a poly-phase
power meter designed to measure electrical loads up to 600V. The DATApro is a four channel logging device designed to measure data provided from outside
sensors that can produce any of the following inputs; 4-20mA, 0-10VDC,
electrical currents, temperature signals, or pulse signals.
-
If I wish to monitor a remote site how do I retrieve my
data?
Our PRO Series instruments (ELITEpro & DATApro) can be ordered
either with an internal modem or device server to be connected to a wired or
unwired LAN system.
-
Which instruments record harmonics and
waveforms? Only our ELITEpro can
monitor harmonics and waveforms and allow you to view it in real time however,
the ELITEpro will not store this data. It will allow you to take a
snapshot to attach to a file.
-
What are the memory capacities of the ELITEpro &
DATApro? The standard memory is 128k
(25,000 records) and the upgraded 512k memory (100,000 records) comes as an
option. Memory capacity is a function of the integration interval, and
recording flags set.
-
Can I upgrade my memory at a later
date? Yes in the form of a factory
upgrade. We also offer upgrades to internal modems. All factory
upgrades include new EPROM's, new batteries, an electrical systems check,
burn-in, and new software.
-
What kind of computer operating systems will the ELITEpro& DATApro instruments work with? Windows 95,98,2000, NT 4.0, or XP.
-
What are the recording intervals of the ELITEpro &
DATApro instruments? 3,15,30 seconds,
1,2,5,10,15,20,30 minutes, and 1,12,24 hours.
-
What kind of current transformers are
available? Three types: split-core,
clamp-on and flexible (Rogowski). You may learn more about available CTs here.
-
Can I use CT's that I currently own with my new
ELITEpro & DATApro instruments? Only if they are shunted to
333mV's. This is the required input for both instruments. The CT inputs of the ELITEpro can handle a maximum of 450mV of AC or DC current.
-
If power to the instrument is lost, does it stop recording
and/or lose saved data? Recording continues using the internal battery, however the
sampling rate may change from every 3 seconds to once per minute to help extend
battery life. Data that has been captured will always be stored
regardless of whether the instrument goes completely dead.
-
Can you do your own graph scaling with the
DATApro? Yes.
-
Can I have an monitored event trigger the start of
monitoring? No, however you can delay
start until a specific date and time.
-
How
long does the battery last with the ELITEpro & DATApro
instruments? The
typical battery life with these instruments is 3 years when the
integration (data collection) interval is 1 minute or longer. The battery life
can be as short as 1 month if the integration interval is set to less than 1
minute. The battery is user replaceable. Contact the factory for
availability and replacement instructions.
-
What
is the sampling rate of the ELITEpro? Sampling rate is the
frequency measured in times per second that a logger reads each sensor.
The ELITEpro reads once every three seconds (except when battery power is
being used then it is once every minute). The integration interval is the
period of time over which the samples that are read during the sampling rate,
are averaged and then stored into the loggers memory.
-
What
is the waveform sampling rate for the ELITEpro? This is the number of points on a given waveform that are
measured and the values used to calculate RMS volts, and watts. The
ELITEpro samples at 128 points per cycle regardless of how often a
channel is read.
-
How
do I connect my ELITEpro or my DATApro to my USB
port? Simply purchase our USB to Serial Port
adapter.
Top of
Page |
|
|
SMARTlogger™
Instruments |
|
-
Will
my MAGlogger be able to sense a load if I just place it on the incoming
line? The MAGlogger can be used successfully without actually
placing it on or near the actual device you are measuring. Sometimes you may
need to experiment with the orientation of the logger or you may need to adjust the sensitivity. The
MAGlogger will sense any signal greater than 40 milligaus. The MAGlogger will not sense a load if the L1 and L2 lines are close together as they tend to
cancel each other out--and yet, if the load is large enough and the sensitivity
on the MAGlogger is turned to its maximum sensitivity, it may sense the load.
-
What type of information are the SMARTlogger
instruments designed to provide? Total running time, transition times, peak load
times, kWh, and more.
-
How many records can a SMARTlogger
store? Memory is rated by number of transition points (on's & off's) and is
8,000.
-
Are TOU (time-of-use) instruments the same as
SMARTloggers? Yes. TOU simply stands for
time-of-use, while SMARTloggers is the trade name we give our series of
TOU loggers.
-
Does
the MAGlogger require me to mount it directly on my dirty, hot, vibrating
motor?
No, you can simply place it next to the incoming power line and the internal
magnetic sensor will sense the flow of electricity and trigger the transition
data.
-
Is
there an instrument I can use to simply monitor the running time of a
stand-alone device that has a cord? Yes, you may use the
CTlogger.
-
If I
use a MAGlogger to monitor a load, can I get kwH
calculations? Yes, by simply asking the software to set the
kW scale factor then reading the results in the summary.
-
How
long does the battery last with the SMARTloggers? The typical battery life of the
SMARTloggers is 5 years. The battery is user replaceable. Contact the
factory for availability. (Note: Older SMARTloggers manufactured before April
2006 have a 7-10 year battery life, but are not user
replaceable.)
Top of
Page |
|
|
Software/Communications |
|
-
The "Total Usage (channel 5) KWh" reported in the Data File Summary does not exactly match the individual channel 5 KWh "Total" number--why? The "Total Usage (channel 5)" value is only updated once per minute. If your integration period is set to less than one minute, channel 5 KWh "Total" column will aquire data that has not been added to the "Total Usage (channel 5)" value. (For example, if your logger is set to 15 second integration and you aquire 1.5 minutes of data--or 6 intervals--that "Total Usage (channel 5)" will not include the final 2 recorded data points.)
-
How
do I scale the graphs to suit my purposes in the software? By
double clicking on the Y or X axis.
-
How
do I zoom-in when working with ELOG software? Simply position the
mouse pointer near the area to be zoomed. Hold the Control (Ctrl) key and
left mouse button down at the same time, then drag the pointer to make a
rectangle that covers the area to be zoomed. Let go of the mouse and
Control Key and the graph will redraw a zoomed portion of the graph. The
graph may be zoomed as many times as desired. Use the View > UnZoom (Ctrl
U), or the key to unzoom, to zoom out again.
-
When
I am monitoring a load that requires more than one channel (such as a 3 Phase -
3 Wire Delta load) which channel shows my totals in my ELOG™ software? When using more than one channel for one load, the
results from each channel need to be added together to obtain the total power
consumption. This is done using the computed channels 5 and 6.
-
Do I need software, and does it have to be ordered
separately?
Yes, software is used to program and start the PRO series (ELOG software) and
SMARTlogger (SMARTware software) series instruments, in addition to retrieving and analyzing
the collected data. If multiple loggers are used, there may not be a need
for multiple copies of the software as the software comes with an unlimited site license.
-
Can I order the communication cables
separately? Yes,
the communications cable can be ordered separately or as part of the
communication package. Communication cables for the weather-tight
enclosure are special and must be ordered specifically when
needed.
-
Once I have the data, can I export it to a spreadsheet or
database?
Yes, data can easily be exported to any ASCII programs like Excel® or
Access®.
-
How will I know if I have sufficient memory to complete my
study? The first page of the 'set-up' table automatically
calculates memory capacity allowing the user to do 'what-if's'.
-
Is the software the same for the ELITEpro and the
DATApro? Yes, the ELOG software is used
for both instruments.
-
Is the software the same for all the
SMARTloggers? Yes, the SMARTware software is
used for all
SMARTlogger instruments.